网络首发:2013-11-20,
纸质出版:2013
移动端阅览
眼前段生物学结构与青光眼激发试验的关系[J]. 中山大学学报(医学科学版), 2013,34(6).
Association of Quantitative Anterior Segment Parameters and Positive Dark-Room Provocative Test in Patients with Narrow Anterior ChamberAngle[J]. Journal of Sun Yat-sen University (Medical Sciences), 2013, 34(6).
【目的】 探讨房角狭窄者眼前段结构参数与青光眼暗室激发试验阳性的相关关系。【方法】 回顾性分析260例房角狭窄者的眼前段生物学参数和青光眼暗室激发试验结果。所有患者应用超声生物显微镜定量测量眼前段生物学参数,包括前房深度(ACD)、瞳孔直径(PD)、晶状体矢高(LV)、周边虹膜厚度(IT)、虹膜膨隆度(IC)、房角开放距离(AOD)、小梁网-睫状突夹角(TCPA)和房角同位关闭的象限数(NPAC);所有患者均完成青光眼暗室激发试验。比较暗室激发试验阳性者与阴者间的眼前段结构差异,分析青光眼暗室激发试验中眼压升高的相关因素。【结果】 房角狭窄者青光眼暗室激发试验的阳性率为27.3%;暗室试验中眼压升高的幅度与AOD(r = -0.249,P < 0.001)、IC(r = -0.125,P = 0.043)负相关,与 IT(r = 0.188,P = 0.002)、NPAC(r = 0.305,P < 0.001)正相关;暗室试验阳性者的IT和NPAC大于阴性者,AOD小于阴性者。【结论】房角和虹膜参数与青光眼暗室激发试验结果相关,房角狭窄、房角同位关闭、厚虹膜是暗室激发试验阳性的危险因素。
【Objective】 To investigate the relationship of positive dark-room provocative test and anterior segment parameters measuredby ultrasound biomicroscopy (UBM) in the patients with narrow anterior chamber angle.【Methods】 Dark-room provocative test and anterior segmentparameters measured by UBM were analyzed retrospectively in two hundred and sixtycases with narrow anterior chamber angle. Anterior chamber depth (ACD), pupil diameter(PD), lens vault (LV), peripheral iris thickness (IT), iris convex (IC), anteriorchamber angle open distance (AOD), trabecular-meshwork ciliaryprocess angle (TCPA), number of positional angle closure (NPAC) were quantitativelyanalyzed. All cases underwent provocative test. Difference of anterior parametresbetween eyes with positive and negative provocative test and parametres correlatedwith IOP elevation were analyzed. 【Results】 Seventy-oneout of 260 patients had IOP elevation more than 8 mmHg at least in one eye. Thetotal positive rate were 27.3%. IOP elevation in dark room provocative test wasnegatively correlated with AOD (r = -0.249, P < 0.001) and IC (r = -0.125, P = 0.043),and positively correlated with IT (r = 0.188, P = 0.002) and NPAC (r = 0.305, P< 0.001). IT(449.91 vs 422.36 ?滋m; P < 0.001) and NPAC (1.59vs 0.62; P < 0.001) were greater and AOD (60.24° vs 98.7°; P < 0.001) was smallerin patients with positive results than those with negative results. 【Conclusions】Parameters of anterior chamber angle and iris were related with positive dark roomtest. Narrower chamber angle, appositional angle closure and thicker iris were riskfactors for positive results in dark room provocative test.
0
浏览量
654
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621
